the perimeter of the plate.. wide range of plate sizing options for a variety of patient anatomies. options for calcaneus fracture management.. They might have you try to extend your leg. Arthrex, Inc. products are designed without any latex components or packaging. Zimmer Biomet or its affiliates unless otherwise indicated, and must To address various types of fractures, the Patella SuturePlate II system offers three types of plates in different sizes. Medial column arthrodesis with VariAx plate. Some people report long-term symptoms of pain or stiffness, and some choose to continue wearing a knee brace for support. locking Foot & Ankle Ankle Fracture Management System A comprehensive set for the treatment of common ankle fracture injuries. Patella SuturePlate System Offers a unique and ultimate rigid method for the accurate reduction of patella fractures. Hand & Wrist PEEKPower Distal Radius Plate A multidirectional, volar plating system made of carbon fiber (CF) reinforced PEEK in combination with titanium screws. Open the catalog to page 5 Arthrex - Plates Plates Ankle Fracture Management System The Ankle Fracture Management System was developed to be the most comprehensive set available for the treatment of ankle fractures. ORTHOLOC System Surgical Technique, These two new plate designs expand upon Zimmer FiberWire is superior in strength to stainless steel wire for tension band fixation of transverse patellar fractures. The demonstration is performed by Dr. Kai Olms. Your healthcare provider may recommend trying to avoid stairs, squatting and bending, when possible, to limit stress on your knee and prevent future complications. The low-profile plates are available in a wide range that The mesh plates, which are offered in short and long lengths, can be cut and contoured to the desired size and shape based on fracture patterns. Designed with the surgeon in mind, the plates have many features to help create a more reproducible procedure: The locking straight plates include a slide hole, which allows slight movement across the fracture line to facilitate the best plate placement. The distinct andsimple-to-use carbon fiber targeting guides (small experience.Mymobilitydelivers continuous data and Non-Locking Screws. K-wire fixation with metal tension band were used for fixation in 315 (70%) patients and cannulated screws were used with tension band for fixation in 133 (30%). Patella Fracture. Most people will be feeling good in about six weeks, and able to return to all of their normal activities within three to six months. Patellar stability and osteosynthesis rates have been shown to improve significantly with locked plates.2 Arthrex mesh plates can be used in conjunction with this set for fixation of these frequently challenging injuries. options for calcaneus fracture management.. Patellar stability and osteosynthesis rates have been shown to improve significantly with locked plates. It covers the incision, the desired outcome, the osteotomy and fixation. Any compromise of the joint surface is likely to lead to degenerative joint disease. We do not endorse non-Cleveland Clinic products or services. the calcaneus will allow good plate/bone apposition. Although tension band fixation allows for reliable osseous union, especially in simple fracture patterns, it still presents several problems. In addition, FiberTape. Some patella fractures are simple, but this small bone is also capable of breaking into many pieces. The targeting guides arerigid for Lisfranc Reconstruction System, Coding, coverage and reimbursement information. Functional outcomes of revision osteosynthesis after failure of surgical treatment of patellar fractures. warnings, precautions, potential adverse effects and patient Recovery can be long, and side effects are common. Its multiple screw holes supposedly offer adequate stabilization of multi-fragment fractures. Arthrex is the first company to obtain FDA clearance for plating in patella fracture indications. . Depending on the force applied, it may create a hairline crack, break into two pieces or it may break into many small pieces. 1 Tension-band wiring and cannulated screws have been the most commonly used techniques for the management of . not be redistributed, duplicated or disclosed, in whole or in part, Biometsexistingnon-locking perimeter plate and the A.L.P.S. The optimal fixation of operatively treated patella fractures continues to evolve (See Fig. Fit for patients Fit for procedures Fit for you Fit for the future Contact Related categories Orthopaedics PEEKPower Tibial Head Fracture Plates Lateral and Posteromedial A combination of titanium locking screws and a radiolucent carbon reinforced PEEK plate. Diagnosis is made radiographically with CT studies often required to assess for intra-articular extension. Calcaneus plates, and are designed to address comminuted fractures features two distinct and anatomically contoured plate designs that Patented SmartLock polyaxial locking technology 1. 2 Arthrex mesh plates can be used in conjunction with this set for fixation of these frequently challenging injuries. Lapidus procedure for hallux valgus correction. Tabs allow the surgeonto place screws into the cuboid, thus 2023 Arthrex, Inc. All rights reserved. address a variety of calcaneus fractures, while meeting the stress Mechanical testing is not necessarily indicative of clinical performance., Quantifying Your Patient Recovery with ZBEdges Persona IQ and the mymobility Care Management Platform, AAOS Las Vegas 03.08.23, Dealers Choice: ORIF vs. Total Hip Replacement AAOS Las Vegas 03.08.23, Zimmer Biomet Announces Fourth Quarter and Full-Year 2022 Financial Results, Zimmer Biomet Announces Webcast and Conference Call of Fourth Quarter 2022 Financial Results, Hindfoot: Calcaneus Fracture, Medial Calcaneal Slide, Small Standard, 2-Hole Learn more Don't. Secondary fixation to the coracoid by using the Dog Bone Button. These cookies do not store any personal information. The Patella Fracture System includes everything needed to repair transverse patella fractures. Coming to a Cleveland Clinic location?Hillcrest Cancer Center check-in changesCole Eye entrance closingVisitation, mask requirements and COVID-19 information, Notice of Intelligent Business Solutions data eventLearn more. Licensed from Prof. D. Wolter, Hamburg, GermanyStryker Corporation or its divisions or other corporate affiliated entities own, use or have applied for the following trademarks or service marks: Anchorage, Stryker, VariAx. Apple Watch and iPhone are trademarks of Apple, Inc., registered in could be slightly varied (outside of the targeting guide) with either They will take X-rays or even a CT scan to define the fracture. Seven new indication specific plates. A patella fracture is a serious injury, which can impact your ability to bend or straighten your knee. 3.5 mm Multi-Directional Locking Screws or 3.5 mm Low Profile The locking patella plate (Arthrex, Munich, Germany) is available in two different specifications: the Arrowplate and the Starplate ( Fig. Are you a medical professional residing in France? A patella fracture will often leave you unable to walk. You also have the option to opt-out of these cookies. Ankle Fracture Plating System, CHARLOTTE Locking screws can be angled 15 for a total range of 30. A recent study evaluated construct failure after an open reduction and plate fixation and reported a construct failure rate of 6.9% of which 1.9% were related to broken plates. Fragility fractures are the clinical outcome of osteoporosis. representative; search this website for additional product Designed with the surgeon in mind, the plates have many features to help create a more reproducible procedure: The locking straight plates include a slide hole, which allows slight movement across the fracture line to facilitate the best plate placement. Calcaneal Fracture System Designed to be the most comprehensive solution for calcaneal fracture fixation perimeter and percutaneous plates. It is a serious type of knee injury that can affect all types of men and women athletes. FiberWire is superior in strength to stainless steel wire for tension band fixation of transverse patellar fractures. All plates have a low-profile thickness of 1.6 mm with screws sitting flush. 2). Screw is also available to compress the plate to the bone. All fibula plates are engineered to work seamlessly with our proven Syndesmosis TightRope implants. 1. FiberTape, 2 mm with Braided Polyblend Suture Blue with Straight Needle, Low Profile Screw, Cannulated, Blunt Tip, 4 x 24 mm, Low Profile Screw, Cannulated, Blunt Tip, 4 x 26 mm, Low Profile Screw, Cannulated, Blunt Tip, 4 x 28 mm, Low Profile Screw, Cannulated, Blunt Tip, 4 x 30 mm, Low Profile Screw, Cannulated, Blunt Tip, 4 x 32 mm, Low Profile Screw, Cannulated, Blunt Tip, 4 x 34 mm, Low Profile Screw, Cannulated, Blunt Tip, 4 x 36 mm, Low Profile Screw, Cannulated, Blunt Tip, 4 x 38 mm, Low Profile Screw, Cannulated, Blunt Tip, 4 x 40 mm, Low Profile Screw, Cannulated, Blunt Tip, 4 x 42 mm, Low Profile Screw, Cannulated, Blunt Tip, 4 x 44 mm, Low Profile Screw, Cannulated, Blunt Tip, 4 x 46 mm, Low Profile Screw, Cannulated, Blunt Tip, 4 x 48 mm, Low Profile Screw, Cannulated, Blunt Tip, 4 x 50 mm, Low Profile Screw, Cannulated, Blunt Tip, 4 x 55 mm, Low Profile Screw, Cannulated, Blunt Tip, 4 x 60 mm. Compared to traditional K-wires, this construct has been shown to be stronger.1. This video demonstrates a calcaneal cuboid fusion. The aim of the PSCG is to dene the PSCG is anatomical. It is, therefore, highly desirable, in patellar fractures to strive for anatomical reduction of the joint surface and stable fixation. for intra-articular fractures of the calcaneus, whereas the small What are the signs and symptoms of a patellar fracture? The mechanism of injury . hole as shown in the illustration below. provide both strength to the inner area of the plate, and The mesh plates combine an MIS plate design with Stryker Corporation or its divisions or other corporate affiliated entities own, use or have applied for the following trademarks or service marks: Anchorage, Stryker, VariAx. The quadriceps and patellar tendon attach to your patella, which normally allows you to flex and extend your knee. It includes 4.0 mm blunttipped cannulated screws that, when used in conjunction with FiberTape as an anterior tension band, creates a. PEEKPower Humeral Fracture Plate Anatomically designed radiolucent multidirectional locking plate made of carbon fiber reinforced PEEK in combination with titanium screws. Current accepted surgical options. Patella SuturePlate II On the other hand, Lee et al. Patella Fracture Repair with Patella SuturePlate Arthrex Europe 539 subscribers Subscribe 24 Save 6.3K views 5 years ago .more .more Notice Age-restricted video (based on Community. Digital care management platform that uses iPhone and Apple Follow the guidance of your healthcare provider and avoid too much activity too soon. Simplicity and adaptability with seven new indication specific plates using the comprehensive locking and non-locking screw system. Plate fixation of patella fractures is a method that allows for more rigid stabilization and earlier mobilization. information.To obtain a copy of the current Instructions for Use The demonstration is performed by Dr. Donald Bohay and John Anderson of Grand Rapids, MI. The procedure uses a Stryker Asnis III 4.0mm cannulated screw and a VariAx Foot oblique t-plate. The set includes everything needed to perform a traditional repair. History. 8,9 At our Level 1 trauma center, 1 fellowship-trained trauma surgeon treats all operative patella fractures with a low profile anterior mesh plate. If you suffer from chronic stiffness or weakness in your joint, you may want to continue wearing a knee brace for support. Solving complicated fractures with simple innovative solutions - Plating that fits. They represent only 1% of all fractures. Advertising on our site helps support our mission. This fracture involves the proximal (upper) portion of the tibia which extends through the articular surface (into the knee joint). Innovative instruments are included along with sternal wire drivers, Weber clamps, drill guides, and Stout wire cutters, giving surgeons all necessary instruments needed in one convenient set. Stainless Steel, Type I Anodized titanium, and machined