Pump lids are all very tight, they need to be. Looks like Ill take it apart tomorrow to see if the impeller is going out or the ceramic bearing may be loose. If that is what is happening to you Im sorry, but your motor is probably gasping its last breaths. "@context": "https://schema.org/",
Running very smoothly and pumping very hard. registration, authorized Is this normal? It is usually set to run at high rpm early morning and that is before sun hits it. When I turn on my clock and put my ear close to the clock I hear the clock sound like its on but my Hayward filter does not turn on and makes no noise. I have a Hayward HeatPro model HP21104T. I have it on a 15 amp breaker with a few other items, the motor after running is very hot to the touch. I do not think its the breakerits relatively new. 6. inspect conduit and wires going from timer to pump, look for water in the conduit, or broken conduit, or rodent damage to wires. The idea is to cut the pipe above the pump, and crank the fitting 1/2 turn tighter, to open the crack, pump it full of superglue and then quickly unthread the pipe out of the pump, at which point the crack will close up, and hopefully seal up. Hi Martha, open the air bleeder, perhaps there is a lot of air in the tank, drawn in by the pump. Hi Tiffany, in most inground pool cases, the pool pump should be powered by a breaker on the home main panel, which powers a breaker on the pool equipment pad sub-panel breaker box. when i reassemble after cleaning, pump works great for about 5 mins even at 30 psi. Filter runs fine at first, but then eventually loses its umph and then the return becomes minimal. I just had a power surge in my area and the heater has been turning on and wont turn off. Automatic restart 2 minutes after error is corrected. We used flocculant and vacuumed through the pump instead of to waste. A lb of DE is by volume, equal to a 1 lb coffee can, or about 4 cups of dry measure. Touch both leads of your meter to the capacitor terminals, does not matter which lead touches which terminal. There is a small sump pump also connected to another breaker inside the breaker box that has no issues, of course it only runs a few minutes when it rains heavy to move water out of the basement. How can I locate and check if a valve is faulty. Does this seem odd or excessive? Ohms reading should be between 0.5 and 1.0 ohms max. Motors have a thermal overload switch to shut off the motor when it gets too hot. Replace with exact MFD number, printed on side. If you want, you can remove the capacitor and wrap it in a heavy cloth, or rubber sheet just in case. info. Pump motors are continuous duty, meaning that they are meant for continuous operation, it wont harm the motor, or cause it to overheat. Even with the cells reverse polarity feature, the scale will still form on the plates. If theres no power at the switch/timer, go back further to the breaker. that would be rare, very rare. But, If you get no noise at all when you turn on the pump, no humming or grinding, or breaker tripping then check all the power connections, and check for power entering the motor, using a multimeter to test the terminals where the 2 wires connect. I was wondering if the Hayward Cyclac Ball Value could be leaking? The stationary switch copper tabs may be bent, or may have a wire crossing between them, have a loose screw or have some other issue that prevents it from opening, and releasing the capacitor. Make sure that the drive is bonded with the bare copper wire and all four screws are secure on the drive. When we turned it on heard a pop and blew fuse. how to watch past broadcasts on twitch. After I installed the ne motor, I pugged it in, started the pump and the breaker tripped. If the blower prover switch opens during the postpurge cycle (heater is not firing) the control will display the error code. Theory and practice | Find, read and cite all the research you need on ResearchGate Fitness View More. Hayward offers environmentally responsible, cutting-edge pool and spa equipment for residential and commercial, in-ground and above-ground pools. started having the problem You dont need a seal plate kit you can just use the shaft seal SPX1600Z2. Hi, I have a filter timer and a cleaner timer that are side-by-side. Works great minus the vacuum created is so great that getting the lid off of the basket is so great a breaker bar is needed to remove it. Hi Davy. Seemed to be operating fine and I was vacuuming pool and lost suction. The Filter Design Flow Rate is usually printed on the label, or can be found online. The pump need not be completely air tight, but has to pull more water than air! Check that the drain plugs are tightly inserted with Teflon tape, and that the pump basket is inserted in the proper way, and is sitting all the way down. Check power at the switch or timer in the same way as the motor, at the other end of the wires running between the switch/timer and motor. Then restarts. My pool pump was running fine until I turned it off. Does anyone know what Im talking about and/or know how to repair? Do you believe I have a bad breaker? If you see an increase in pump pressure, ensure that there is no blockage preventing the flow. If the gears are moving, then power should be coming out of the timeclock to the motor. I have a Hayward North Star that I rebuilt with new motor, shaft seal, all new rubber seals, impeller, and diffuser. Just hoping for some feed back and the name plate is missing from the Tristar Motor, to actually know the exact motor we have? I have a Hayward sp 2603 vsp pump which is a year old has been working fine but 2 days ago I turned it on it ran about 1 minute, it cut off and on the display it says error code 11 and it will not run. A corroded part will be rusted and will start to disintegrate over time. So, it either needs a new motor, or new internal parts, or possibly a whole new pump. put on high speed. Hi Jacob, I would check the connections of the wires first. I replaced the breaker and electrical plug which showed some damage but motor does not start and breaker still tripping If your shaft IS spinning freely, other causes of a tripped breaker include loose wiring, broken wires, water in the wire conduit, wires inside the motor touching other wires or the metal motor casing, insect infestation in the time clock. Please ignore my previous question I put a slight bend in the end of the wrench and was able to get a grip on the shaft , When I opened my pool the pump hummed and did not start. Is this normal operation or should I look into replacing the strainer cover o ring? Hi Michael, that could be a bad or weak capacitor, or a loose wire to the pump motor or to the outlet, or a bad power cord. Should have the hard plastic side facing the motor and the soft rubber side facing the impeller. Find these plugs and remove them by loosening the wingnut and wiggling it out. If the gears are not moving, either the motor for the clock is dead, or insects or lizard is stuck in the gears, or the breaker is tripped or off, or the breaker is bad. Hi Sam, I suppose a dead battery (capacitor), but there would be some noise or hum, as the motor tried to start, then would trip the breaker. Basically it ran normal and then would get loud, and then go back to normal. Any ideas why? Had a ball stuck under the skimmer basket, pump got hot and now will not turn back on. Thats unusual, shouldve fixed it. It is a H400FDN series. This morning I decided to open fully all valves while pump was on low and no flow was detected. Any thoughts? You can use a bent paperclip to ream out the orifices. I have a Hayward H250 pool heater with a digital display. There should be no continuity. Could the filter be plumbed backwards possibly? Have a Hayward SuperPump. Step 4: Verify your pumps pressure. Unusual, but it could be the only problem, I would replace the capacitor with the same size (match the MFD number), and check that the shaft rotates freely when mounted to the pump. When the pump comes on a massive amount of bubbles comes out of the return line in the bottom of the pool. If there is air in the basket it hums away loudly and sucks great to prime and fill the basket (the saltwater thing even appears to be working). My question to you is what to do from here. Please advise. Put a meter on the terminal board, and see if the voltage coming into the motor is fluctuating or dropping off, when the motor cycles. Many two speed split capacitor motors use the capacitor to boost it to high speed, check the capacitor for bulging, splits, leaking or loose wires, or test for capacitance, or test with new one. Troubleshooting pool heaters is a methodical process, or a process of elimination. It may not display this or other websites correctly. I would appreciate any kind of trouble shooting and support. Troubleshooting Your Hayward Aqua Rite System - http://bit.ly/2RC8myGHayward AquaRite Parts - http://bit.ly/2NPGXbjHow To Clean a Hayward AquaRite Turbo Cell - http://bit.ly/2TPpK5IStabilizer - http://bit.ly/3aCeEa7SUBSCRIBE for FREE swimming pool care and maintenance videos every week: http://bit.ly/SubscribeINYO ****VISIT our blog for weekly swimming pool tips, tricks, and more! Hi Marsha, Ive had this question a lot this year. Using a Slime Bag, attached to the pool return, to act as a secondary filter, would be a solution. I primed the pump and was ready to add DE compund. Old broken wires inside of the conduit could be the problem. Move switch to center position and adjust dial to a percentage that you think it needs. If not that, it could be a loose wire connection. I replaced the pump thinking it was bad. Third guess would be that the connections were not tight on the new motor. Fourth possibility is that the other lines (skimmer or main drain) are partially clogged or valves closed, not allowing enough water to enter pump, while vacuuming. But just like any sort of equipment, even the most well-made products sometimes need repairs. New pump probably not a shaft seal problem, just loose clamp band or volute bolts. Occasionally the salt level on the Hayward Aqua Rite may not match the actual salt level of the pool. Hi and thanks for all this knowledge! I also replaced the seals. Is this rare? Overheating can be a short across the windings, or it can be other major faults within the motor. Hi Rob, I think its a one-year warranty? It need not be a fancy $100 meter, it can be a $10 meter from Radio Shack. Or a stuck skimmer weir. If so, put the meter on the terminals where to cord connects inside the motor and see if there is power there. Hi Steve, this can be from reduced flow, like a VS pump running on low speed, and some water vaporizing into steam. Below is a list of common issues that can arise with your Hayward pool heater. Zeolite Market Share In 2022 | Top Players [ Shanghai Hengye, Zeotech Corp, Blue Pacific Minerals (BPM), UOP (Honeywell) ] In-Depth Analysis, Forecast to 2027 with Top Countries Data | A Answered on 5/26/2022 by InyoPools Product Specialist Craig C.. Hello J. Camfrog Pro Extreme Atau Gold - Camfrog Indonesia. Thanks. As soon as I hook it up and it starts pumping water the pump slows down and struggles, the sound is very noticeable. You must log in or register to reply here. To spin the shaft, to find out of it spins freely, open up the rear of the pump motor, with power off, and use your fingers to spin the shaft. Look at the diagram on the top center of the motor, which may provide some help, if not, call Hayward (908) 355-7995 (U.S.). "keywords": "hayward pool pump",
You find these in our valve parts department or use one of our multiport valve rebuild kits. For either sand or DE, if you experience high pressure or poor filtration after backwashing or cleaning, try a Pool Filter Cleaner product to deep clean the filter. Articles and resources for swimming pool owners and DIYers. Wire size inside socket too small (cant carry the current). Got pump from a friend and he had no problems. My pump is one horse power. The pump may be reversible, able to accept either 115V or 230V, so the incoming voltage must match the set-up, +/- 10%. You can get locally at an electric motor repair shop. If it does not, keep reading. Hi Vic, pool pump motors have a thermal overload switch that will shut down the motor if temps get too hot. If power is tested at these points, I would check the motor terminals. Pumps normal pressure and pulls enough volume to keep bakery full. Would the lack of enough sand cause the water to gush out of the top of the filter? Products, View Mark, if you can hear the motor winding up and down, then it could be the cord. Thank you for the quick response. Hi Susan, hmm thats quite a conundrum! But most plastic impellers are closed nowadays, with non-visible vanes. The capacitor is the black cylinder on the left side, you can replace the capacitor at a low cost. the , . Does a Hayward super pump wired on 230v have to have a controller?.. If you had a multiport valve, you could put it on recirculate and verify, but since perflex have no such valve, the only other test would be to actually plumb around the filter, by installing a bypass valve and line, or just temporarily routing plumbing around the filter, to bypass the filter completely. . Turned it off and then tried it again and it hummed for a few and the something glowed red and then stopped humming. Hi John, if the outlet is GFCI, check the TEST button, it may have tripped. PDF | On Jan 1, 2009, Eduardo Keegan and others published Cognitive-behavior therapy. Also look for any burn marks on the wire terminal board, or any crimped wires running round the rear of the motor. Free, Pool Equipment Parts: Make your Own Repairs, https://www.intheswim.com/p/hayward-super-pump-pool-pump-motor-1-5-hp-threaded-shaft, https://www.intheswim.com/p/hayward-super-pump-shaft-seal-assembly-spx1600z2, http://waterheatertimer.org/How-to-wire-Hayward-two-speed-pump.html, https://hayward-pool-assets.com/assets/documents/pools/pdf/manuals/super-pump-vs-S2603VSP.pdf?fromCDN=true, https://www.intheswim.com/c/filter-parts?pcode=208&scode=SOCIBLOG, https://www.totallyhayward.com/techservices/attachments/Serial%20Number%20Read%20REVISED%201-2012.pdf, https://www.intheswim.com/images/PDFs/E1964-Manual.pdf, https://hayward-pool-assets.com/assets/documents/pools/pdf/manuals/tristar-vs-S3202VSP.pdf?fromCDN=true, https://www.intheswim.com/c/pump-parts?pcode=208&scode=SOCIBLOG, https://www.intheswim.com/p/hayward-spring-seal-w-seat-spx1250xz2c. Pump is primed and water is coming out of the returns. There is an o-ring on the union, and also on the valve stem, and they can start leaking over time. I believe there a water volume calculator, that can help us size the motor, the originally company who installed is not in business. switch in the center. The motor spins CCW? Inherited an old Hayward super pump that hums but doesnt turn over, checked the shaft which moves smoothly and replaced the starter capacitor to no avail. It can also just be a really dirty filter, or a clogged pump impeller. Third, could be clogging in the filter, or bad filter sand, if you have a sand filter. The water level is good. Checked to see that there was no short in the wire with an ohms meter . On traditional intermatic time clocks, you also have to make sure the timer dogs are tight, or they can slip, use pliers to tighten the nut tighter to avoid. First eliminate water flow issues, then gas flow issues, and finally the low voltage electric currents that run between pool heater components. Just push the red button back in. Please consider. If it is reversible is lists voltage on the label as 115V/230V, but if 230V only, it just says 230V. Third, is there a valve closed after the filter, or some other obstruction? Hope that helps! Any ideas on how to fix this issue?? thanks. Had it running today at high rpm and totally turned off after about 20 minutes. Or, it could be that the motor is cavitating, and restricting the return side somewhat may balance the flow, if you have a valve or bypass arrangement, or can plug one of the returns, for testing. Maybe sand it down briefly and WD-40 it after it comes off. Next step would be to remove the cover and put your leads on the terminal board, right where each wire connects. Another oddity is both failure are upon Spring re-opening,and the pumps ran flawlessly throughout each summer? Flow switches require a minimum flow fate of 11 gallons per minute to stay consistently closed, Water temperature is below 50 degrees F. (The cell output scales back to 20% once it reaches 60 degrees F and shuts off at 50 degrees F.). The pump will always start in high speed, and stay in high speed for a few minutes after starting, to ensure full prime. The Aqua Rite is protected by a 20 amp mini ATO fuse located on the circuit board above the cell connector. Did not raise red flags, amature lol. Was running fine. Maybe the transformer is not functioning properly? When, Swimming pool pumps that are noisy can keep you from enjoying peaceful naps by the pool, or can keep your neighbors up, In-Floor pool cleaners have been around since the 70's when they became the answer to the complaints about traditional pool cleaners. Some times it has overheated, it did re start, but I want to make sure that the motor is supposed to run continuously. Cap is fine, so I lost. "image": {
If the motor is fried, you can either replace the motor and shaft seal or spend more, and replace the entire pump (although the motor is the only thing you would really need). Poseer una casa es la piedra angular de la riqueza tanto la riqueza financiera como la seguridad emocional. Is the wire the correct size wire? I live in Tampa Florida. Full membership to the IDM is for researchers who are fully committed to conducting their research in the IDM, preferably accommodated in the IDM complex, for 5 Fitness View More. We have a c48l2n134b3 pump. They are cheap and easy to replace. If the salt cell is clean but the salt reading is off, the Aqua Rite will need to be recalibrated. The filter pressure on low should only be a few psi. Good luck ~, I have a salt water inground pool the other day i noticed my pressure is going up and down from 14psi to like 4 to 6 then back up even couple of mins. http://www.inyopools.com/blogSHOP at our online store! Mendorong partisipasi dunia dalam pengembangan teknologi jaringan baru, and vinylfor the first time ever on camera. I just have a problem with the motor pump, I turn ON Saturday morning and left all day working, On Sunday morning I try to turn on the pump but it only make a noise but water dont flow then it stop working, then on Monday do the same thing it only make noise for 3 minutes then it stop working. Use a flashlight, and you should see gears moving thru the small view hole. power to my pool pump & timer quit working at the same time. I have 2 extension cords running to plug it in. HELP!!! Hi Jim, make sure the shaft of the motor (and the impeller) is spinning freely, rust can build up internally, and create a frozen pump in spring. High will run fine but next day I have to do the same, start with low and switch to high. Plate appeared to be good. Chapter 1: The Evil Emperor's Son. I can turn the temperature up but not down. There can be multiple reasons for a pool pump not priming correctly. Step 4: If none of the previous steps solved the problem, replace your flow switch. spun and is loosely spinning. Hi Jim, yes it could be leaking, around the stem that sticks up thru the valve body and attaches to the handle. I know I have power going to the unit, as I can hear it go on and off in the transformer, when I hit the switch. Below is the troubleshooting guide for Hayward pool heater error codes. It had been running ok this summer. Some pumps are stronger than some hose, so check to see if the hose is not collapsing under the suction, during the issue. Hi Jeanette, somewhat normal with sand filters I would say first. If you have power there, and the motor is making no sound then I would inspect closely for a loose wire on the terminal board, or a loose switch in the back, or loose capacitor wire. I have a F5 code and service light is on. If you pipes are underground, it could also be happening, if flex pipe was used and you have been using chlorine tablets in the skimmer. Oh, and prepare yourself, a new motor or pump may be needed soon. You can check power in, on the incoming wires, and power out (with timer ON), on the outgoing wires that go to the motor. Hi, I have a H250PED2. After coming across that it would no longer produce chlorine after 6 years, I decided to buy a new cell. Impeller replacement is only ever really needed for breakage or other severe damage, so if it aint broke. The problem lies where the power dies! They have never had this issue in the pass, a salt water chlorinator was added to the system last year with no problems. There must be a leak. I even removed the outflow from the filter and ran that directly in case the filter was clogged. With a test meter, you check power at the motor, and it should be within 10% of 120V or 240V, whichever the motor is wired for, and if not, the power is traced back to a point where it full power is found, on the meter. You can use a pool putty to seal up some incoming leaks, but sometimes new parts are needed. The correct replacement would be the AquaRite Main PCB (OEM) GLX-PCB-RITE. Replace with the exact same capacitor (look at the MFD rating printed on the capacitor). Superpump lid gaskets are a square cut gasket that can come out of the groove easily, be sure it is seated properly, and lube it with Teflon pool lube regularly. Humming noise is usually associated with a bad capacitor, a black cylinder at 9 oclock in the rear of the motor. or if i let it rest for like 10 to 15 min it will start right up on its own when i hit the switch. The motor runs but does not Blower will operate until error condition is corrected. If all is well then 99% sure it would be the capacitor, weak and needs replacement. Nothing tripped. Hoses popping off could also indicate a high pressure problem after the filter, such as obstructed return lines, such as plugged or blocked wall returns, or closed valves. Occasionally the salt level on the Hayward Aqua Rite may not match the actual salt level of the pool. ' Checked to make sure nothing was blocking it. It could possibly be a bad cord, or a bad outlet, or loose wires on pump or outlet. If the pump runs without water for very long it will burn up the shaft seal, and if run for hours and days, can literally melt the pump, sometimes even catch fire (rarely), even with a small amount of water in it. Do you have any advice? The trick is the little plug on the electrical panel MUST be moved to either 230 (up one) or to 115 (down). What happens when you switch the output to super-chlorinate? When we first started both up there were no issues, however now when the heater kicks on the pump starts to make a high pitched noise. Hi Davy, Im trying to remove the impeller from a Hayward 1 HP superpump. It seems the pump is more powerful than last year ? The pump itself works great. Then, take a look at the capacitor, located at 9 oclock. Pressing on/off buttom followed only by click sound of switch. What could be wring? We just opened our pool up cleaned everything out put new D.E. if this is installed below pool water level, also close the isolation valves, to keep the water in the pool, and avoid soaking your socks! Do I need to use lube on the gasket, how much sand should be in the filter? Hi We just bought a new Hayward Powerflo Matrix pump and filter. "@type": "ImageObject",
If not, I would suspect voltage issues, especially with the overheating, be sure pump is wired to accept the incoming voltage (115V or 230V), and it doesnt fluctuate more than 10%, +/- . Air leaks or other obstructions BEFORE the pump (including a clogged impeller), will cause lower than normal filter pressure. Typically, any dilemmas with your Hayward pool pump are likely related to either electrical or plumbing situations. Whats the best and safest way to troubleshoot? Use Teflon pool lube on the pump lid o-ring, reapply every 4 months. Checked pump, and appeared that pump had to keep priming . Sun was beating on it. The air may be there on high speed too, its just not noticeable. I dont want to over tighten it. All check ok. Shut it off & starting looking for help online. First time pool owner (obviously dont know what we are doing). Thanks, Steve DeGray. The pump is currently configured for 115v. Hi Kenny, not to my knowledge, you should see some display even without gas hookup. I was going to try one of those next, as it seems impossible to keep water in the line without it draining into the pool. Morning , everything was working fine with my Hayward pump. What and how should I go about diagnosing this? Hi Stephen, your spa waterfall, is that a spillover or an actual waterfall feature? The shaft is accessed in the rear of the motor, behind the centrifugal switch. Not normal, but cant see a reason why that would cause the seal to fail. With the pump off, remove the basket and reach your hand back into the eye of the impeller. Check the breaker inside the house, make sure its not tripped. It worked when fine for a couple of times but only clicks now. I tried starting again one morning but the pump wont start. Not too bad of a repair, if you want to attempt yourself. Replaced the flow sensor as it seemed to run when lower RPMs on the pump and it now seems to cut it off when the RPMs on the pump drop like it should, and it will cut off when temperature reaches set heat of 93 for the spa. Contact a professional for further assistance. look for a hi-voltage/low-voltage diagram on the motor label. hayward super pump C48L2N134B1. Second be sure that you are delivering 230V (+/- 10%) and that the motor is set to accept 230V (some are reversible to accept 115V too). ), hard to tell until the pump can be tested. Not all horsepowers are created equal, meaning that a 1hp Hayward Super II pumps a lot more water than a 1hp Hayward Super I, or Max-Flo. Any suggestions or ideas as to why it is not producing chorine in regular mode? dhp faux leather club chair; hanna salinity tester calibration; If plumbed backwards into the PUMP and RETURN ports, it would exhibit these symptoms. I couldnt believe it..after two weeks and a new pump! I turned off my pool at the control box for 24 hours as I needed a union replaced at the salt cell. Step 1: With your pump running, double-check the positions of your valves. Yes, that sounds like a filter problem, clogged up with algae or oily substance. Pump is less than 3 years old. I have a new Power-Flo Matrix pump. 1. Check if the pump will now run. this is the black cylinder in the rear, at 9 oclock. Thanks. Hi my spa empties into the pool when the spa is turned on. I have a Hayward pump for my above ground pool, it is two years old. I think you need two timers, usually, unless it can deliver 240 to the filter pump and 120 to the booster, at the same time. Students and professors will find thorough, current coverage of all business research topics presented with a balance of theory and practical A Answered on 5/26/2022 by InyoPools Product Specialist Craig C.. Hello J. When the problem is after the pump impeller, like a clogged filter, closed return valve or clogged return line, the pressure will be higher than normal. Have no power at all going to my control panel. Hi Stacey, the build-up of pressure usually means that the filter is clogged, as you likely know. https://www.google.com/search?client=firefox-b-1-d&q=hayward+h-150+manual the first pdf link is the older model H150, the second .pdf link is the newer H150 models, altho it may not make a difference. It seems to only operate in the highest speed. I doubt you damaged anything, or have any big issues, should be OK. Any tips? It looks like its coming from in between the motor and pump.Am I correct in thinking I need a new seal plate kit? If the meter reads zero, and stays at zero the capacitor is bad. Pumps need 120V, +/- 10%, so maybe the voltage is fluctuating, from loose connection from breaker to outlet, or a loose breaker. If the amps on either reading show zero (0), then you should replace your PC Board. I just replaced my pump/motor at the start of this swimming season. Good thing is our power company is offer rebates for new energy efficient pumps. Just to let you know, the pump is in a well ventilated shed with nothing else around it. From the EcoStar technical guide: Check impeller and motor shaft for freedom of movement. Automatic restart is 2 minutes after the error is corrected. I have a 2 year old Hayward Pump 1 HP wired for 110 with 20 Amp breaker.
Running very smoothly and pumping very hard. registration, authorized Is this normal? It is usually set to run at high rpm early morning and that is before sun hits it. When I turn on my clock and put my ear close to the clock I hear the clock sound like its on but my Hayward filter does not turn on and makes no noise. I have a Hayward HeatPro model HP21104T. I have it on a 15 amp breaker with a few other items, the motor after running is very hot to the touch. I do not think its the breakerits relatively new. 6. inspect conduit and wires going from timer to pump, look for water in the conduit, or broken conduit, or rodent damage to wires. The idea is to cut the pipe above the pump, and crank the fitting 1/2 turn tighter, to open the crack, pump it full of superglue and then quickly unthread the pipe out of the pump, at which point the crack will close up, and hopefully seal up. Hi Martha, open the air bleeder, perhaps there is a lot of air in the tank, drawn in by the pump. Hi Tiffany, in most inground pool cases, the pool pump should be powered by a breaker on the home main panel, which powers a breaker on the pool equipment pad sub-panel breaker box. when i reassemble after cleaning, pump works great for about 5 mins even at 30 psi. Filter runs fine at first, but then eventually loses its umph and then the return becomes minimal. I just had a power surge in my area and the heater has been turning on and wont turn off. Automatic restart 2 minutes after error is corrected. We used flocculant and vacuumed through the pump instead of to waste. A lb of DE is by volume, equal to a 1 lb coffee can, or about 4 cups of dry measure. Touch both leads of your meter to the capacitor terminals, does not matter which lead touches which terminal. There is a small sump pump also connected to another breaker inside the breaker box that has no issues, of course it only runs a few minutes when it rains heavy to move water out of the basement. How can I locate and check if a valve is faulty. Does this seem odd or excessive? Ohms reading should be between 0.5 and 1.0 ohms max. Motors have a thermal overload switch to shut off the motor when it gets too hot. Replace with exact MFD number, printed on side. If you want, you can remove the capacitor and wrap it in a heavy cloth, or rubber sheet just in case. info. Pump motors are continuous duty, meaning that they are meant for continuous operation, it wont harm the motor, or cause it to overheat. Even with the cells reverse polarity feature, the scale will still form on the plates. If theres no power at the switch/timer, go back further to the breaker. that would be rare, very rare. But, If you get no noise at all when you turn on the pump, no humming or grinding, or breaker tripping then check all the power connections, and check for power entering the motor, using a multimeter to test the terminals where the 2 wires connect. I was wondering if the Hayward Cyclac Ball Value could be leaking? The stationary switch copper tabs may be bent, or may have a wire crossing between them, have a loose screw or have some other issue that prevents it from opening, and releasing the capacitor. Make sure that the drive is bonded with the bare copper wire and all four screws are secure on the drive. When we turned it on heard a pop and blew fuse. how to watch past broadcasts on twitch. After I installed the ne motor, I pugged it in, started the pump and the breaker tripped. If the blower prover switch opens during the postpurge cycle (heater is not firing) the control will display the error code. Theory and practice | Find, read and cite all the research you need on ResearchGate Fitness View More. Hayward offers environmentally responsible, cutting-edge pool and spa equipment for residential and commercial, in-ground and above-ground pools. started having the problem You dont need a seal plate kit you can just use the shaft seal SPX1600Z2. Hi, I have a filter timer and a cleaner timer that are side-by-side. Works great minus the vacuum created is so great that getting the lid off of the basket is so great a breaker bar is needed to remove it. Hi Davy. Seemed to be operating fine and I was vacuuming pool and lost suction. The Filter Design Flow Rate is usually printed on the label, or can be found online. The pump need not be completely air tight, but has to pull more water than air! Check that the drain plugs are tightly inserted with Teflon tape, and that the pump basket is inserted in the proper way, and is sitting all the way down. Check power at the switch or timer in the same way as the motor, at the other end of the wires running between the switch/timer and motor. Then restarts. My pool pump was running fine until I turned it off. Does anyone know what Im talking about and/or know how to repair? Do you believe I have a bad breaker? If you see an increase in pump pressure, ensure that there is no blockage preventing the flow. If the gears are moving, then power should be coming out of the timeclock to the motor. I have a Hayward North Star that I rebuilt with new motor, shaft seal, all new rubber seals, impeller, and diffuser. Just hoping for some feed back and the name plate is missing from the Tristar Motor, to actually know the exact motor we have? I have a Hayward sp 2603 vsp pump which is a year old has been working fine but 2 days ago I turned it on it ran about 1 minute, it cut off and on the display it says error code 11 and it will not run. A corroded part will be rusted and will start to disintegrate over time. So, it either needs a new motor, or new internal parts, or possibly a whole new pump. put on high speed. Hi Jacob, I would check the connections of the wires first. I replaced the breaker and electrical plug which showed some damage but motor does not start and breaker still tripping If your shaft IS spinning freely, other causes of a tripped breaker include loose wiring, broken wires, water in the wire conduit, wires inside the motor touching other wires or the metal motor casing, insect infestation in the time clock. Please ignore my previous question I put a slight bend in the end of the wrench and was able to get a grip on the shaft , When I opened my pool the pump hummed and did not start. Is this normal operation or should I look into replacing the strainer cover o ring? Hi Michael, that could be a bad or weak capacitor, or a loose wire to the pump motor or to the outlet, or a bad power cord. Should have the hard plastic side facing the motor and the soft rubber side facing the impeller. Find these plugs and remove them by loosening the wingnut and wiggling it out. If the gears are not moving, either the motor for the clock is dead, or insects or lizard is stuck in the gears, or the breaker is tripped or off, or the breaker is bad. Hi Sam, I suppose a dead battery (capacitor), but there would be some noise or hum, as the motor tried to start, then would trip the breaker. Basically it ran normal and then would get loud, and then go back to normal. Any ideas why? Had a ball stuck under the skimmer basket, pump got hot and now will not turn back on. Thats unusual, shouldve fixed it. It is a H400FDN series. This morning I decided to open fully all valves while pump was on low and no flow was detected. Any thoughts? You can use a bent paperclip to ream out the orifices. I have a Hayward H250 pool heater with a digital display. There should be no continuity. Could the filter be plumbed backwards possibly? Have a Hayward SuperPump. Step 4: Verify your pumps pressure. Unusual, but it could be the only problem, I would replace the capacitor with the same size (match the MFD number), and check that the shaft rotates freely when mounted to the pump. When the pump comes on a massive amount of bubbles comes out of the return line in the bottom of the pool. If there is air in the basket it hums away loudly and sucks great to prime and fill the basket (the saltwater thing even appears to be working). My question to you is what to do from here. Please advise. Put a meter on the terminal board, and see if the voltage coming into the motor is fluctuating or dropping off, when the motor cycles. Many two speed split capacitor motors use the capacitor to boost it to high speed, check the capacitor for bulging, splits, leaking or loose wires, or test for capacitance, or test with new one. Troubleshooting pool heaters is a methodical process, or a process of elimination. It may not display this or other websites correctly. I would appreciate any kind of trouble shooting and support. Troubleshooting Your Hayward Aqua Rite System - http://bit.ly/2RC8myGHayward AquaRite Parts - http://bit.ly/2NPGXbjHow To Clean a Hayward AquaRite Turbo Cell - http://bit.ly/2TPpK5IStabilizer - http://bit.ly/3aCeEa7SUBSCRIBE for FREE swimming pool care and maintenance videos every week: http://bit.ly/SubscribeINYO ****VISIT our blog for weekly swimming pool tips, tricks, and more! Hi Marsha, Ive had this question a lot this year. Using a Slime Bag, attached to the pool return, to act as a secondary filter, would be a solution. I primed the pump and was ready to add DE compund. Old broken wires inside of the conduit could be the problem. Move switch to center position and adjust dial to a percentage that you think it needs. If not that, it could be a loose wire connection. I replaced the pump thinking it was bad. Third guess would be that the connections were not tight on the new motor. Fourth possibility is that the other lines (skimmer or main drain) are partially clogged or valves closed, not allowing enough water to enter pump, while vacuuming. But just like any sort of equipment, even the most well-made products sometimes need repairs. New pump probably not a shaft seal problem, just loose clamp band or volute bolts. Occasionally the salt level on the Hayward Aqua Rite may not match the actual salt level of the pool. Hi and thanks for all this knowledge! I also replaced the seals. Is this rare? Overheating can be a short across the windings, or it can be other major faults within the motor. Hi Rob, I think its a one-year warranty? It need not be a fancy $100 meter, it can be a $10 meter from Radio Shack. Or a stuck skimmer weir. If so, put the meter on the terminals where to cord connects inside the motor and see if there is power there. Hi Steve, this can be from reduced flow, like a VS pump running on low speed, and some water vaporizing into steam. Below is a list of common issues that can arise with your Hayward pool heater. Zeolite Market Share In 2022 | Top Players [ Shanghai Hengye, Zeotech Corp, Blue Pacific Minerals (BPM), UOP (Honeywell) ] In-Depth Analysis, Forecast to 2027 with Top Countries Data | A Answered on 5/26/2022 by InyoPools Product Specialist Craig C.. Hello J. Camfrog Pro Extreme Atau Gold - Camfrog Indonesia. Thanks. As soon as I hook it up and it starts pumping water the pump slows down and struggles, the sound is very noticeable. You must log in or register to reply here. To spin the shaft, to find out of it spins freely, open up the rear of the pump motor, with power off, and use your fingers to spin the shaft. Look at the diagram on the top center of the motor, which may provide some help, if not, call Hayward (908) 355-7995 (U.S.). "keywords": "hayward pool pump",
You find these in our valve parts department or use one of our multiport valve rebuild kits. For either sand or DE, if you experience high pressure or poor filtration after backwashing or cleaning, try a Pool Filter Cleaner product to deep clean the filter. Articles and resources for swimming pool owners and DIYers. Wire size inside socket too small (cant carry the current). Got pump from a friend and he had no problems. My pump is one horse power. The pump may be reversible, able to accept either 115V or 230V, so the incoming voltage must match the set-up, +/- 10%. You can get locally at an electric motor repair shop. If it does not, keep reading. Hi Vic, pool pump motors have a thermal overload switch that will shut down the motor if temps get too hot. If power is tested at these points, I would check the motor terminals. Pumps normal pressure and pulls enough volume to keep bakery full. Would the lack of enough sand cause the water to gush out of the top of the filter? Products, View Mark, if you can hear the motor winding up and down, then it could be the cord. Thank you for the quick response. Hi Susan, hmm thats quite a conundrum! But most plastic impellers are closed nowadays, with non-visible vanes. The capacitor is the black cylinder on the left side, you can replace the capacitor at a low cost. the , . Does a Hayward super pump wired on 230v have to have a controller?.. If you had a multiport valve, you could put it on recirculate and verify, but since perflex have no such valve, the only other test would be to actually plumb around the filter, by installing a bypass valve and line, or just temporarily routing plumbing around the filter, to bypass the filter completely. . Turned it off and then tried it again and it hummed for a few and the something glowed red and then stopped humming. Hi John, if the outlet is GFCI, check the TEST button, it may have tripped. PDF | On Jan 1, 2009, Eduardo Keegan and others published Cognitive-behavior therapy. Also look for any burn marks on the wire terminal board, or any crimped wires running round the rear of the motor. Free, Pool Equipment Parts: Make your Own Repairs, https://www.intheswim.com/p/hayward-super-pump-pool-pump-motor-1-5-hp-threaded-shaft, https://www.intheswim.com/p/hayward-super-pump-shaft-seal-assembly-spx1600z2, http://waterheatertimer.org/How-to-wire-Hayward-two-speed-pump.html, https://hayward-pool-assets.com/assets/documents/pools/pdf/manuals/super-pump-vs-S2603VSP.pdf?fromCDN=true, https://www.intheswim.com/c/filter-parts?pcode=208&scode=SOCIBLOG, https://www.totallyhayward.com/techservices/attachments/Serial%20Number%20Read%20REVISED%201-2012.pdf, https://www.intheswim.com/images/PDFs/E1964-Manual.pdf, https://hayward-pool-assets.com/assets/documents/pools/pdf/manuals/tristar-vs-S3202VSP.pdf?fromCDN=true, https://www.intheswim.com/c/pump-parts?pcode=208&scode=SOCIBLOG, https://www.intheswim.com/p/hayward-spring-seal-w-seat-spx1250xz2c. Pump is primed and water is coming out of the returns. There is an o-ring on the union, and also on the valve stem, and they can start leaking over time. I believe there a water volume calculator, that can help us size the motor, the originally company who installed is not in business. switch in the center. The motor spins CCW? Inherited an old Hayward super pump that hums but doesnt turn over, checked the shaft which moves smoothly and replaced the starter capacitor to no avail. It can also just be a really dirty filter, or a clogged pump impeller. Third, could be clogging in the filter, or bad filter sand, if you have a sand filter. The water level is good. Checked to see that there was no short in the wire with an ohms meter . On traditional intermatic time clocks, you also have to make sure the timer dogs are tight, or they can slip, use pliers to tighten the nut tighter to avoid. First eliminate water flow issues, then gas flow issues, and finally the low voltage electric currents that run between pool heater components. Just push the red button back in. Please consider. If it is reversible is lists voltage on the label as 115V/230V, but if 230V only, it just says 230V. Third, is there a valve closed after the filter, or some other obstruction? Hope that helps! Any ideas on how to fix this issue?? thanks. Had it running today at high rpm and totally turned off after about 20 minutes. Or, it could be that the motor is cavitating, and restricting the return side somewhat may balance the flow, if you have a valve or bypass arrangement, or can plug one of the returns, for testing. Maybe sand it down briefly and WD-40 it after it comes off. Next step would be to remove the cover and put your leads on the terminal board, right where each wire connects. Another oddity is both failure are upon Spring re-opening,and the pumps ran flawlessly throughout each summer? Flow switches require a minimum flow fate of 11 gallons per minute to stay consistently closed, Water temperature is below 50 degrees F. (The cell output scales back to 20% once it reaches 60 degrees F and shuts off at 50 degrees F.). The pump will always start in high speed, and stay in high speed for a few minutes after starting, to ensure full prime. The Aqua Rite is protected by a 20 amp mini ATO fuse located on the circuit board above the cell connector. Did not raise red flags, amature lol. Was running fine. Maybe the transformer is not functioning properly? When, Swimming pool pumps that are noisy can keep you from enjoying peaceful naps by the pool, or can keep your neighbors up, In-Floor pool cleaners have been around since the 70's when they became the answer to the complaints about traditional pool cleaners. Some times it has overheated, it did re start, but I want to make sure that the motor is supposed to run continuously. Cap is fine, so I lost. "image": {
If the motor is fried, you can either replace the motor and shaft seal or spend more, and replace the entire pump (although the motor is the only thing you would really need). Poseer una casa es la piedra angular de la riqueza tanto la riqueza financiera como la seguridad emocional. Is the wire the correct size wire? I live in Tampa Florida. Full membership to the IDM is for researchers who are fully committed to conducting their research in the IDM, preferably accommodated in the IDM complex, for 5 Fitness View More. We have a c48l2n134b3 pump. They are cheap and easy to replace. If the salt cell is clean but the salt reading is off, the Aqua Rite will need to be recalibrated. The filter pressure on low should only be a few psi. Good luck ~, I have a salt water inground pool the other day i noticed my pressure is going up and down from 14psi to like 4 to 6 then back up even couple of mins. http://www.inyopools.com/blogSHOP at our online store! Mendorong partisipasi dunia dalam pengembangan teknologi jaringan baru, and vinylfor the first time ever on camera. I just have a problem with the motor pump, I turn ON Saturday morning and left all day working, On Sunday morning I try to turn on the pump but it only make a noise but water dont flow then it stop working, then on Monday do the same thing it only make noise for 3 minutes then it stop working. Use a flashlight, and you should see gears moving thru the small view hole. power to my pool pump & timer quit working at the same time. I have 2 extension cords running to plug it in. HELP!!! Hi Jim, make sure the shaft of the motor (and the impeller) is spinning freely, rust can build up internally, and create a frozen pump in spring. High will run fine but next day I have to do the same, start with low and switch to high. Plate appeared to be good. Chapter 1: The Evil Emperor's Son. I can turn the temperature up but not down. There can be multiple reasons for a pool pump not priming correctly. Step 4: If none of the previous steps solved the problem, replace your flow switch. spun and is loosely spinning. Hi Jim, yes it could be leaking, around the stem that sticks up thru the valve body and attaches to the handle. I know I have power going to the unit, as I can hear it go on and off in the transformer, when I hit the switch. Below is the troubleshooting guide for Hayward pool heater error codes. It had been running ok this summer. Some pumps are stronger than some hose, so check to see if the hose is not collapsing under the suction, during the issue. Hi Jeanette, somewhat normal with sand filters I would say first. If you have power there, and the motor is making no sound then I would inspect closely for a loose wire on the terminal board, or a loose switch in the back, or loose capacitor wire. I have a F5 code and service light is on. If you pipes are underground, it could also be happening, if flex pipe was used and you have been using chlorine tablets in the skimmer. Oh, and prepare yourself, a new motor or pump may be needed soon. You can check power in, on the incoming wires, and power out (with timer ON), on the outgoing wires that go to the motor. Hi, I have a H250PED2. After coming across that it would no longer produce chlorine after 6 years, I decided to buy a new cell. Impeller replacement is only ever really needed for breakage or other severe damage, so if it aint broke. The problem lies where the power dies! They have never had this issue in the pass, a salt water chlorinator was added to the system last year with no problems. There must be a leak. I even removed the outflow from the filter and ran that directly in case the filter was clogged. With a test meter, you check power at the motor, and it should be within 10% of 120V or 240V, whichever the motor is wired for, and if not, the power is traced back to a point where it full power is found, on the meter. You can use a pool putty to seal up some incoming leaks, but sometimes new parts are needed. The correct replacement would be the AquaRite Main PCB (OEM) GLX-PCB-RITE. Replace with the exact same capacitor (look at the MFD rating printed on the capacitor). Superpump lid gaskets are a square cut gasket that can come out of the groove easily, be sure it is seated properly, and lube it with Teflon pool lube regularly. Humming noise is usually associated with a bad capacitor, a black cylinder at 9 oclock in the rear of the motor. or if i let it rest for like 10 to 15 min it will start right up on its own when i hit the switch. The motor runs but does not Blower will operate until error condition is corrected. If all is well then 99% sure it would be the capacitor, weak and needs replacement. Nothing tripped. Hoses popping off could also indicate a high pressure problem after the filter, such as obstructed return lines, such as plugged or blocked wall returns, or closed valves. Occasionally the salt level on the Hayward Aqua Rite may not match the actual salt level of the pool. ' Checked to make sure nothing was blocking it. It could possibly be a bad cord, or a bad outlet, or loose wires on pump or outlet. If the pump runs without water for very long it will burn up the shaft seal, and if run for hours and days, can literally melt the pump, sometimes even catch fire (rarely), even with a small amount of water in it. Do you have any advice? The trick is the little plug on the electrical panel MUST be moved to either 230 (up one) or to 115 (down). What happens when you switch the output to super-chlorinate? When we first started both up there were no issues, however now when the heater kicks on the pump starts to make a high pitched noise. Hi Davy, Im trying to remove the impeller from a Hayward 1 HP superpump. It seems the pump is more powerful than last year ? The pump itself works great. Then, take a look at the capacitor, located at 9 oclock. Pressing on/off buttom followed only by click sound of switch. What could be wring? We just opened our pool up cleaned everything out put new D.E. if this is installed below pool water level, also close the isolation valves, to keep the water in the pool, and avoid soaking your socks! Do I need to use lube on the gasket, how much sand should be in the filter? Hi We just bought a new Hayward Powerflo Matrix pump and filter. "@type": "ImageObject",
If not, I would suspect voltage issues, especially with the overheating, be sure pump is wired to accept the incoming voltage (115V or 230V), and it doesnt fluctuate more than 10%, +/- . Air leaks or other obstructions BEFORE the pump (including a clogged impeller), will cause lower than normal filter pressure. Typically, any dilemmas with your Hayward pool pump are likely related to either electrical or plumbing situations. Whats the best and safest way to troubleshoot? Use Teflon pool lube on the pump lid o-ring, reapply every 4 months. Checked pump, and appeared that pump had to keep priming . Sun was beating on it. The air may be there on high speed too, its just not noticeable. I dont want to over tighten it. All check ok. Shut it off & starting looking for help online. First time pool owner (obviously dont know what we are doing). Thanks, Steve DeGray. The pump is currently configured for 115v. Hi Kenny, not to my knowledge, you should see some display even without gas hookup. I was going to try one of those next, as it seems impossible to keep water in the line without it draining into the pool. Morning , everything was working fine with my Hayward pump. What and how should I go about diagnosing this? Hi Stephen, your spa waterfall, is that a spillover or an actual waterfall feature? The shaft is accessed in the rear of the motor, behind the centrifugal switch. Not normal, but cant see a reason why that would cause the seal to fail. With the pump off, remove the basket and reach your hand back into the eye of the impeller. Check the breaker inside the house, make sure its not tripped. It worked when fine for a couple of times but only clicks now. I tried starting again one morning but the pump wont start. Not too bad of a repair, if you want to attempt yourself. Replaced the flow sensor as it seemed to run when lower RPMs on the pump and it now seems to cut it off when the RPMs on the pump drop like it should, and it will cut off when temperature reaches set heat of 93 for the spa. Contact a professional for further assistance. look for a hi-voltage/low-voltage diagram on the motor label. hayward super pump C48L2N134B1. Second be sure that you are delivering 230V (+/- 10%) and that the motor is set to accept 230V (some are reversible to accept 115V too). ), hard to tell until the pump can be tested. Not all horsepowers are created equal, meaning that a 1hp Hayward Super II pumps a lot more water than a 1hp Hayward Super I, or Max-Flo. Any suggestions or ideas as to why it is not producing chorine in regular mode? dhp faux leather club chair; hanna salinity tester calibration; If plumbed backwards into the PUMP and RETURN ports, it would exhibit these symptoms. I couldnt believe it..after two weeks and a new pump! I turned off my pool at the control box for 24 hours as I needed a union replaced at the salt cell. Step 1: With your pump running, double-check the positions of your valves. Yes, that sounds like a filter problem, clogged up with algae or oily substance. Pump is less than 3 years old. I have a new Power-Flo Matrix pump. 1. Check if the pump will now run. this is the black cylinder in the rear, at 9 oclock. Thanks. Hi my spa empties into the pool when the spa is turned on. I have a Hayward pump for my above ground pool, it is two years old. I think you need two timers, usually, unless it can deliver 240 to the filter pump and 120 to the booster, at the same time. Students and professors will find thorough, current coverage of all business research topics presented with a balance of theory and practical A Answered on 5/26/2022 by InyoPools Product Specialist Craig C.. Hello J. When the problem is after the pump impeller, like a clogged filter, closed return valve or clogged return line, the pressure will be higher than normal. Have no power at all going to my control panel. Hi Stacey, the build-up of pressure usually means that the filter is clogged, as you likely know. https://www.google.com/search?client=firefox-b-1-d&q=hayward+h-150+manual the first pdf link is the older model H150, the second .pdf link is the newer H150 models, altho it may not make a difference. It seems to only operate in the highest speed. I doubt you damaged anything, or have any big issues, should be OK. Any tips? It looks like its coming from in between the motor and pump.Am I correct in thinking I need a new seal plate kit? If the meter reads zero, and stays at zero the capacitor is bad. Pumps need 120V, +/- 10%, so maybe the voltage is fluctuating, from loose connection from breaker to outlet, or a loose breaker. If the amps on either reading show zero (0), then you should replace your PC Board. I just replaced my pump/motor at the start of this swimming season. Good thing is our power company is offer rebates for new energy efficient pumps. Just to let you know, the pump is in a well ventilated shed with nothing else around it. From the EcoStar technical guide: Check impeller and motor shaft for freedom of movement. Automatic restart is 2 minutes after the error is corrected. I have a 2 year old Hayward Pump 1 HP wired for 110 with 20 Amp breaker.